SCC2-P
Controller and Sensor (X2 OS) for Air Differential Pressure
The SCC2 is a programmable controller and sensor with communication capabilities. Each control loop may use 2 PI sequences and 2 binary stages. The SCC2 comes with a built in RS485 communication interface that allows peer to peer communication with an operation terminal such as OPT1-(2TH)-VC.
Communication plug-in allow for integration of the controller into a network. These modules are described in their own manual. Currently available are plug-ins for BACnet and MODBUS.
Flexible application configuration is made with a parameter-setting routine using the standard operation terminal.
Complete parameter sets may be copied by use of an accessory called AEC-PM2 or exchanged with a PC using an RS485-USB converter and the EasySet program.
Applications
- Pressure measurement in the field of heating, ventilation and air conditioning
- Measuring of air flow velocity
- Measuring and control of positive or negative pressure for example for clean rooms
- Supervision of critical pressures
Features
- Pressure measurement from ± 25 Pa up to ± 500 Pa (± 0.1 to ± 2 in H2O)
- “Zeroing” of differential pressure sensor supported
- Two universally configurable control loops:
- Functions for dehumidifying, set point shift and cascade control
- Multiple auxiliary functions: heat-cool auto changeover, automatic enable, set point compensation
- Free heating and cooling with economizer function based on enthalpy or temperature
- Differential, averaging, min and max functions, enthalpy and dew point calculations
- Transmitter function for inputs and set points
- Universal analog outputs (VDC, mA)
- Relay output with a normally open and a normally closed contact (SPDT)
- Passive input for temperature NTC or open contact
- 8 freely assigned alarm conditions, selectable state of outputs on alarm condition
- Password protected programmable user and control parameters
Ordering
Product name |
Product No. |
Functions |
Description |
SCC2-P1-200.101U-OP | 40-300206 | Differential pressure sensor and built-in display Pressure range ± 25 Pa (± 0.1 in H2O) |
Air differential pressure controller and sensor with - 2 control loops - 1 digital output - 1 analog output - communication (MOD/BAC) |
SCC2-P2-200.101U-OP | 40-300207 | Differential pressure sensor and built-in display Pressure range ± 100 Pa (± 0.4 in H2O) |
|
SCC2-P3-200.101U-OP | 40-300208 | Differential pressure sensor and built-in display Pressure range ± 500 Pa (± 2 in H2O) |
|
SCC2-P1-200.101U-MOD | 40-300209 | Differential pressure sensor Pressure range ± 25 Pa (± 0.1 in H2O) Communicating with Modbus RTU or ASCII |
|
SCC2-P2-200.101U-MOD | 40-300210 | Differential pressure sensor Pressure range ± 100 Pa (± 0.4 in H2O) Communicating with Modbus RTU or ASCII |
|
SCC2-P3-200.101U-MOD | 40-300211 | Differential pressure sensor Pressure range ± 500 Pa (± 2 in H2O) Communicating with Modbus RTU or ASCII |
|
SCC2-P1-200.101U-BAC | 40-300212 | Differential pressure sensor Pressure range ± 25 Pa (± 0.1 in H2O) Communicating with BACnet MS/TP |
|
SCC2-P2-200.101U-BAC | 40-300213 | Differential pressure sensor Pressure range ± 100 Pa (± 0.4 in H2O) Communicating with BACnet MS/TP |
|
SCC2-P3-200.101U-BAC | 40-300214 | Differential pressure sensor Pressure range ± 500 Pa (± 2 in H2O) Communicating with BACnet MS/TP |
Accessories
Downloads
Operation Manual
Install Sheet
Application Notes
- 70-00-0218C X2-BACnet V1_3.pdf
- 70-00-0990B Wiring Guide.pdf
- 70-00-0737A X2-Engineering Manual V1-5.pdf
- 70-00-0636_Application-Note_X2_parameter_access_through_BACnet.pdf
- 70-00-0635_Application-Note X2_parameter_access_MODBUS_1-2.pdf
- 70-00-0290_X2-MOD_V1-2.pdf
Certificates
Archive