SCC-T1-Tp - PTx

#

Programmable temperature transmitter for PT100 and PT1000 probes for a wide and accurate measurement range

The transmitter measures the temperature through a PT100 or PT1000 platinum film element.

SCC-T1-TP1 measures a PT100 element, SCC-T1-TP2 measures a PT1000 sensing element. The temperature range may be customized by DIP switches or by programming.

The output signal range and type may be customized by jumpers or by programming. Standard output signal ranges are 0-10VDC, 2-10VDC, 0-20mA and 4-20mA. Other ranges can be set on the optional built-in operation terminal “OPC-S V2” or by connecting an external operation terminal “OPA-S / OPU-S”.

For more details, see the operation manual in the downloads section.

Applications

  • For indoor, outdoor, duct, immersion temperature measurement in the field of heating, ventilation and air conditioning applications 
  • Measure exactly the temperature range you need 
  • Recording of minimum and maximum values for critical environments 
  • Supervision of critical temperatures

Type Overview (see ordering / accessories for details)

Standard SCC SCC with duct probe SCC with built-in operation terminal

SCC-T1-TP2AMC-1_TOP_web.jpg

 

SDC SCC 350x300.jpg

SCC-T1-Tp2-08/-16/-24

SCC-T1-TP2-OP+AMC-1 TOP.jpg

OPC-S-V2

 

Features

  • Precision temperature measurement for different ranges and accuracies 
  • Minimum and maximum temperature memory 
  • 0…10V, 0…20mA or 2…10V, 4…20mA measuring signal output, selectable with jumpers 
  • DIP switch for temperature range pre-set 
  • Alternative temperature signal ranges programmable (operation terminal) 
  • Selectable averaging filter for the measurement signal 
  • Optional LCD display (OPC-S V2) or external display (OPA-S / OPU-S) 
  • Status LED 
  • Modbus RTU/ASCII RS485 for monitoring and configuration 
  • Copy of settings with accessory (AEC-PM2) 

 Selectable Temperature range by DIP switch

  SCC-T1-TP1 SCC-T1-TP2
DIP [°C] [°F] [°C] [°F]
0 -40…60 °C  -40…140 °F -40...400 °C -40...752 °F
1 0…50 °C 32…122 °F -40…60 °C  -40…140 °F
2 0…100 °C 32…212 °F 0…50 °C 32…122 °F
3 0…200 °C 32…392 °F 0…100 °C 32…212 °F
4 -60…200 °C -76…392 °F 0…250 °C 32…482 °F
5 -40…150 °C -40…302 °F -40…150 °C -40…302 °F
6 -20…80 °C  -4…176 °F  -20…80 °C  -4…176 °F 
7 -15…35 °C 5…95 °F -15…35 °C 5…95 °F

 

Ordering

 Product name  Product No.  Description
 SCC-T1-Tp1-1  40-300258  Temperature transmitter for PT100 sensor (sensor not included) 
 with 2 cable glands 
 SCC-T1-Tp2-1  40-300157  Temperature transmitter for PT1000 sensor (sensor not included) 
 with 2 cable glands 
 SCC-T1-Tp2-08-1  40-300159  Temperature transmitter with PT1000 duct sensor probe, length 8 cm
 SCC-T1-Tp2-16-1  40-300111  Temperature transmitter with PT1000 duct sensor probe, length 16 cm
 SCC-T1-Tp2-24-1  40-300112  Temperature transmitter with PT1000 duct sensor probe, length 24 cm
 SCC-T1-Tp2-MOD-1  40-300241  Temperature transmitter, for PT1000 sensor (sensor not included)
 with 2 cable glands and Modbus communication
 SCC-T1-Tp2-08-MOD-1  40-300242  Temperature transmitter, with PT1000 duct sensor probe, length 8 cm
 and Modbus communication
 SCC-T1-Tp2-16-MOD-1  40-300243  Temperature transmitter, with PT1000 duct sensor probe, length 16 cm
 and Modbus communication
 SCC-T1-Tp2-24-MOD-1  40-300244  Temperature transmitter, with PT1000 duct sensor probe, length 24 cm
 and Modbus communication

Dimensions

Dimensions mm (inch)

SCC-T1-Tp1-1 or SCC-T1-Tp2-1

 

SCC-T1-Tp2-08/-16/-24 (SCC with duct probe)

 

 

Connections

Connections

SCC-T1-Tp2-1

 

SCC-T1-Tp2-08/-16/-24 (SCC with duct probe)

 

Accessories

#
Temperature Sensors
Passive temperature sensors for a large variety of installation options and applications
#
OPC-S-V2 - Built-in Display
Operation and display for intelligent transmitters
#
OPA-S - Remote Display
Operation and display for intelligent transmitters
#
OPU-S - Remote Display
Operation and display for intelligent transmitters

Downloads

Operation Manual

Install Sheet

Application Notes

Certificates

Archive