SDC2-T - Duct Mounted
Duct mounted Controller and Sensor (X2 OS) for Temperature
The SDC2-T is a programmable controller and sensor with communication capabilities. Each control loop may use 2 PI sequences and 2 binary stages. The SDC2-T comes with a built in RS485 communication interface that allows peer to peer communication with an operation terminal such as OPT1-(2TH)-VC.
Communication plug-in allow for integration of the controller into a network. These modules are described in their own manual. Currently available are plug-ins for BACnet and MODBUS.
Flexible application configuration is made with a parameter-setting routine using the standard operation terminal.
Complete parameter sets may be copied by use of an accessory called AEC-PM2 or exchanged with a PC using an RS485-USB converter and the EasySet program.
Applications
- Ventilation control
- Air measurement
- Zone control
- VAV control
Features
- Two universally configurable control loops:
- Functions for dehumidifying, set point shift and cascade control
- Multiple auxiliary functions: heat-cool auto changeover, automatic enable, set point compensation
- Free heating and cooling with economizer function based on enthalpy or temperature
- Differential, averaging, min and max functions, enthalpy and dew point calculations
- Transmitter function for inputs and set points
- Universal analog outputs (VDC, mA) and one relay with a normally open and a normally closed contact (SPDT)
- 8 freely assigned alarm conditions, selectable state of outputs on alarm condition
- Password protected programmable user and control parameters
- Measures temperature
Ordering
Item name |
Item code |
Functions |
Description |
SDC2-16-T-200.101U-1 |
40-300169 |
Temperature sensor |
duct mounted controller and sensor with communication 2 control loops |
SDC2-16-T-200.101U-MOD-1 |
40-300170 |
Temperature sensor with Modbus RTU or ASCII communication |
|
SDC2-16-T-200.101U-BAC-1 |
40-300160 |
Temperature- and humidity sensor with BACnet® communication |
Accessories
Downloads
Operation Manual
Install Sheet
Application Notes
- 70-00-0218C X2-BACnet V1_3.pdf
- 70-00-0990B Wiring Guide.pdf
- 70-00-0925B X2-ModbusTCP V1_1.pdf
- 70-00-0899A X2 BACnetIP V1_1.pdf
- 70-00-0737A X2-Engineering Manual V1-5.pdf
- 70-00-0636_Application-Note_X2_parameter_access_through_BACnet.pdf
- 70-00-0635_Application-Note X2_parameter_access_MODBUS_1-2.pdf
- 70-00-0290_X2-MOD_V1-2.pdf
Certificates
Archive