SD-T - Sonde de température pour gaine de ventilation

Capteur de température passive pour montage sur conduit
The SD-T is duct temperature sensor which measures the temperature by use of a glass packed thermistor with a negative temperature coefficient (NTC), a platinum film (PT) or a nickel thin layer (NI) based probe. Its resistance changes according to the temperature. The change follows a specified curve.
Applications
- On return air ducts to measure room temperatures
- On supply air ducts to measure heating/cooling supply air
- As frost protection sensor
- As input for standard controls equipment
Features
- Thermistors and PT sensing elements to fit your system
- Simple and secure installation
- Wide range of temperature probes
Ordering
12 cm sensor
| Item name | Item code | Probe type | Description | Cable length |
| SD-Tn3-12-2 | 40-200014 | NTC 3 kΩ at 25 ºC |
B25/50: 3935 |
2 m, PVC cable |
| SD-Tn10-12-2 | 40-200002 | NTC 10 kΩ at 25 ºC | B25/50: 3935 | |
| SD-Tn11-12-2 | 40-200015 | B25/50: 3380 | ||
| SD-Tn12-12-2 | 40-200089 | B25/50: 3630 | ||
| SD-Tn20-12-2 | 40-200016 | NTC 20 kΩ at 25 ºC | B25/50: 4200 | |
| SD-Tn100-12-2 | 40-200017 | NTC 100 kΩ at 25 ºC | B25/50: 4200 | |
| SD-Tp1-12-2 | 40-200023 | PT100 | EN 60751 | |
| SD-Tp2-12-2 | 40-200024 | PT1000 | EN 60751 | |
| SD-Tk5-12-2 | 40-200025 | NI1000 | 5000 ppm/K | |
| SD-Tn10-12-2H | 40-200150 | NTC 10 kΩ at 25 ºC | B25/50: 3935 | 2 m, FEP cable |
| SD-Tn10-12-2P | 40-200152 | NTC 10 kΩ at 25 ºC | B25/50: 3935 | 2 m, Plenum rated cable |
20 cm sensor
| Item name | Item code | Probe type | Description | Cable length |
| SD-Tn3-20-2 | 40-200018 | NTC 3 kΩ at 25 ºC |
B25/50: 3935 |
2 m, PVC cable |
| SD-Tn10-20-2 | 40-200003 | NTC 10 kΩ at 25 ºC | B25/50: 3935 | |
| SD-Tn11-20-2 | 40-200020 | B25/50: 3380 | ||
| SD-Tn12-20-2 | 40-200103 | B25/50: 3630 | ||
| SD-Tn20-20-2 | 40-200021 | NTC 20 kΩ at 25 ºC | B25/50: 4200 | |
| SD-Tn100-20-2 | 40-200022 | NTC 100 kΩ at 25 ºC | B25/50: 4200 | |
| SD-Tp1-20-2 | 40-200026 | PT100 | EN 60751 | |
| SD-Tp2-20-2 | 40-200027 | PT1000 | EN 60751 | |
| SD-Tk5-20-2 | 40-200028 | NI1000 | 5000 ppm/K | |
| SD-Tn10-20-2H | 40-200151 | NTC 10 kΩ at 25 ºC | B25/50: 3935 | 2 m, FEP cable |
| SD-Tn10-20-2P | 40-200153 | NTC 10 kΩ at 25 ºC | B25/50: 3935 | 2 m, Plenum rated cable |
Accessories

AMI-S - Poche d’immersion pour capteurs de températures
Puits thermométriques en acier oxydable (poche d’immersion) pour capteurs de températures
Downloads
Fiche technique
Manuel d'utilisation
Manuel de paramétrage
Les manuels de paramétrage avec codes d'accès aux paramètres sont réservés aux partenaires agréés : Espace partenaires / Devenir partenaire
Manuel d'installation
Note d'application
Certificats