About Us
Product Security & Vulnerability Disclosure Policy - X2 system
Vector Controls GmbH / Vector Controls LLC
Last updated: 20 November 2026 - Version 1.0
Vector Controls takes the security of its products seriously. We welcome reports from security researchers, customers and integrators, and we work with reporters to verify, fix and disclose issues responsibly. This page describes how to report a vulnerability, what you can expect from us, how long we provide security updates, and where to find our EU declarations of conformity and security advisories - in line with the EU Cyber Resilience Act (Regulation (EU) 2024/2847).
Products covered - the X2 system
| Product | What it is | Security updates delivered by |
|---|---|---|
| X2 | HVAC controller | by Vector Controls only (no field update; see Support period and security updates) |
| AEX-IP | Wi-Fi / Ethernet communication module for the X2 (web interface, Modbus TCP or BACnet/IP, EasySet link) | signed firmware update through the module's web interface |
| EasySet | configuration software for the X2 (Windows; macOS): programs controllers over USB / RS-485 or through the AEX-IP | new versions on the download page of https://vectorcontrols.com; EasySet shows an update notice (check at start, can be switched off) |
| EasyX2 | app for Windows, macOS, Android and iOS: finds X2 controllers with an AEX-IP module (from 2.3.0 also IO3 units) in the local network, shows values, opens the module's web page, sets up the WLAN of a new module | Google Play, App Store; Windows and macOS: download page, Windows with an update notice in the app |
Reporting a vulnerability
If you believe you have found a security vulnerability in a product of the X2 system, please contact us:
- Contact form: vectorcontrols.com contact form, reason Security
- Message: start with
Vulnerability report - <product>(for exampleVulnerability report - EasyX2 app)
To help us respond quickly, please include where possible:
- the affected product and version: module firmware version (module About screen), app version and platform (Windows / Android / iOS), EasySet version (Settings > About EasySet) with the operating system and how EasySet was connected (USB / RS-485 or through the AEX-IP), X2 version;
- a description of the vulnerability and its possible impact;
- steps to reproduce or a proof of concept; and
- any suggested mitigation.
Please give us a reasonable opportunity to investigate and fix the issue before you disclose it publicly (see Coordinated disclosure below). If you are not sure which product is affected, just send the report - we route it internally.
Safe harbour for good-faith research
We will not pursue or support legal action against researchers who, in good faith:
- make a real effort to avoid privacy violations, data loss and service disruption;
- test only on devices and installations they own or are allowed to test, never on equipment in operation that belongs to others;
- do not take, change or destroy data beyond the minimum needed to show the issue; and
- give us reasonable time to fix the issue before public disclosure.
Activity in line with this policy is considered authorised, and we will work with you to understand and solve the issue quickly.
What you can expect from us
- Acknowledgement of your report within 3 business days.
- A first assessment (valid or not, severity, likely time to fix) within 10 business days.
- A fix or mitigation within 30 days for critical vulnerabilities (CVSS 9.0-10.0), 60 days for high (CVSS 7.0-8.9) and 90 days or the next release for medium / low.
- Regular updates on the progress of the fix.
- Credit for your discovery when the fix is published, if you would like to be named.
We do not run a paid bug-bounty programme.
Coordinated disclosure
We follow coordinated disclosure. We aim to release a fix or mitigation and publish an advisory together with you, at the latest 90 days after the report. If an issue is being actively exploited, we may act faster and we fulfil our reporting obligations under the CRA (Article 14: early warning within 24 hours, notification within 72 hours), in addition to the times above. We ask that public disclosure is agreed with us, so that users can update before details are released.
Scope
In scope
- X2 controllers.
- AEX-IP firmware: the web interface, Modbus TCP, BACnet/IP, the EasySet link and the firmware update.
- EasySet configuration software on Windows and macOS: the program files it opens and saves, its connections to the controller (USB / RS-485, and over the network through the AEX-IP), the AEX-IP login, the update check and the installer.
- EasyX2 app on Windows, macOS, Android and iOS (devices: AEX-IP modules, from 2.3.0 IO3 units): discovery of modules, login to a module, display of the module web page, WLAN setup of a new module, data stored on the PC / phone, Windows update check.
Out of scope
- Attacks that need physical disassembly of a device, or full control of the user's PC or phone (malware, rooted / jailbroken device).
- Flaws in operating systems, web view runtimes or app stores (please report them to the vendor; we assess whether our products are affected).
- Social engineering of Vector Controls staff or customers.
- Vulnerabilities in third-party networks or systems the products are only connected to.
- Reports produced only by automated scanners without a demonstrated, product-specific impact.
Support period and security updates
Vector Controls provides free security updates for the products of the X2 system during the support period. The support period is defined for the X2 system as a whole (X2 controllers, AEX-IP, EasySet, EasyX2 app): security updates until at least December 2037. Every unit / licence placed on the market gets at least 5 years of security updates after its sale - if a product is still sold after December 2032, the end date is extended accordingly (reviewed every year with the product roadmap).
| Product | Security updates until | How updates are delivered |
|---|---|---|
| X2 | 12/2037 (at least; extended if still sold after 12/2032) | X2 controllers have no field-update function. Firmware is updated only by Vector Controls with a programmer (factory or service) or by exchanging the unit; configuration tools and bus modules cannot change it. |
| AEX-IP (firmware) | 12/2037 (at least; extended if still sold after 12/2032) | firmware update through the web interface; updates are signed (ECDSA) and checked on the module before installation; firmware older than the last security fix is refused |
| EasySet | 12/2037 (at least; extended if still sold after 12/2032) | new EasySet versions on the download page of https://vectorcontrols.com. EasySet checks for a new version when it starts (can be switched off in its settings) and shows a notice; it does not download or install automatically. The installer is not code-signed - download it only from https://vectorcontrols.com |
| EasyX2 app | 12/2037 (at least; extended if still sold after 12/2032) | Android / iOS: Google Play and the App Store. Windows: the app shows an update notice (check at start, can be switched off, and "Check now" in Settings) with a button to the download page; the app does not download or install automatically. The Windows installer is not code-signed yet - download it only from https://vectorcontrols.com |
Keep operating systems up to date: the EasyX2 app uses the system web view (Microsoft Edge WebView2, Android System WebView, Apple WKWebView), which is updated by the OS vendor.
Secure deployment guidance
The X2 system is made for a protected building-automation network. It is not designed for direct connection to the Internet. To operate it securely:
- Place the devices on a separate network / VLAN, behind a firewall towards the office network and the Internet that lets no connection from outside reach the devices; no port forwarding; remote access only over a VPN.
- Change the default credentials of the AEX-IP module on first commissioning. The EasyX2 app has no default password; it asks for the module password on the first login.
- Each AEX-IP firmware variant has one fieldbus protocol, BACnet/IP or Modbus TCP. It is always on and has no authentication (protocol design), so restrict access by network separation. The EasySet port (8001) opens only for a PC whose user logged in as admin, and the admin can switch it off.
- The web interface of AEX-IP V1.3 and of IO3 units uses HTTPS (self-signed certificate; the EasyX2 app pins it at the first connection); older AEX-IP firmware (V1.2) uses HTTP. Keep all of them on the protected network segment.
- Use EasySet on a PC in the protected network segment and keep the program and backup files of your controllers in a protected place.
- Install security updates for all products of the system.
Details: the security sections of the product manuals (available from Vector Controls on request).
EU declarations of conformity
Our EU declarations of conformity are published on their own page: https://vectorcontrols.com/en_eu/support/cert.
Security advisories
Advisories for fixed vulnerabilities are listed here, newest first. Each advisory names the affected products and versions, the fixed version (per platform for the app), the severity and what to do until the update is installed.
No security advisories have been published yet.
Changes to this policy
We may update this policy from time to time. The current version and its date are shown at the top of this page.