SDC2-THCQ - Duct mount
Duct mount controller and sensor (X2 OS) for temperature, humidity, CO2 and air quality (VOC)
The SDC2 is a programmable controller and sensor with communication capabilities. Each control loop may use 2 PI sequences and 2 binary stages. The SDC2 comes with a built in RS485 communication interface that allows peer to peer communication with an operation terminal such as OPT1-(2TH)-VC.
Communication plug-in allow for integration of the controller into a network. These modules are described in their own manual. Currently available are plug-ins for BACnet and MODBUS.
Flexible application configuration is made with a parameter-setting routine using the standard operation terminal.
Complete parameter sets may be copied by use of an accessory called AEC-PM2 or exchanged with a PC using an RS485-USB converter and the EasySet program.
Applications
- Ventilation control
- Air measurement
- Zone control
- VAV control
Features
- Two universally configurable control loops:
- Functions for dehumidifying, set point shift and cascade control
- Multiple auxiliary functions: heat-cool auto changeover, automatic enable, set point compensation
- Free heating and cooling with economizer function based on enthalpy or temperature
- Differential, averaging, min and max functions, enthalpy and dew point calculations
- Transmitter function for inputs and set points
- Universal analog outputs (VDC, mA) and one relay with a normally open and a normally closed contact (SPDT)
- 8 freely assigned alarm conditions, selectable state of outputs on alarm condition
- Password protected programmable user and control parameters
- Measures temperature, humidity, CO2 and VOC
Ordering
Product Name | Product No. | Functions | ||||||||||||||||||||||||||||||
SDC2-16-C-200.101U-1 | 40-300167 |
|
||||||||||||||||||||||||||||||
SDC2-16-TH-210.102U-1 | 40-300171 | |||||||||||||||||||||||||||||||
SDC2-16-THQ-210.102U-1 | 40-300168 | |||||||||||||||||||||||||||||||
SDC2-16-THCQ-210.102U-1 | 40-300164 | |||||||||||||||||||||||||||||||
SDC2-16-TH-210.102U-MOD-1 | 40-300172 | |||||||||||||||||||||||||||||||
SDC2-16-THC-210.102U-MOD-1 | 40-300174 | |||||||||||||||||||||||||||||||
SDC2-16-THQ-210.102U-MOD-1 | 40-300162 | |||||||||||||||||||||||||||||||
SDC2-16-THCQ-210.102U-MOD-1 | 40-300165 | |||||||||||||||||||||||||||||||
SDC2-16-TH-210.102U-BAC-1 | 40-300166 | |||||||||||||||||||||||||||||||
SDC2-16-THC-210.102U-BAC-1 | 40-300173 | |||||||||||||||||||||||||||||||
SDC2-16-THQ-210.102U-BAC-1 | 40-300161 | |||||||||||||||||||||||||||||||
SDC2-16-THCQ-210.102U-BAC-1 | 40-300163 | |||||||||||||||||||||||||||||||
Pre-Configured Versions | ||||||||||||||||||||||||||||||||
SDC2-16-TH-210.102U-1-W8 | 40-300171-W8 |
|
||||||||||||||||||||||||||||||
SDC2-16-TH-210.102U-1-W28 | 40-300171-W28 | |||||||||||||||||||||||||||||||
SDC2-16-TH-210.102U-1-W9 | 40-300171-W9 | |||||||||||||||||||||||||||||||
SDC2-16-TH-210.102U-1-W29 | 40-300171-W29 |
Accessories
Downloads
Operation Manual
Install Sheet
Application Notes
Certificates
Archive